# WindX Connection Manager

> Source: https://manual.pvxplus.com/windx/connectionmrg

The **WindX Connection Manager** utility is designed to assist users who have multiple thin-client connections to multiple hosts. It provides users with the ability to define and save connection information in a control file, which can be recalled later to simplify connection.

![](https://manual.pvxplus.com/migration-assets/9072b8d1c0cf988fd813f379a35b3d520a560862c25eebb7884fe441beeaf8b9.jpg)

To invoke the **Connection Manager**, use one of the following methods:

| **Location** | **Method** |
| --- | --- |
| From the **[PxPlus IDE Main Launcher](https://manual.pvxplus.com/pxplus-ide/ide-main-launcher)** | Expand the *Client Server* category and select *Launch Workstation*. |
| From the Windows Start menu | Locate *WindX Plugin* and select *Client Launcher*. |
| From the PxPlus Command line or a program | Run the "launcher" program found in the WindX directory.<br>Note:  <br>The normal install for PxPlus and WindX creates a shortcut in the Start menu:  <br>  <br> "\<install dir>\\pxplus.exe" launcher  <br> (starting directory is \<install dir>\\windx)  <br>  <br>To force the Connection Manager to immediately connect to a specific server, specify the connection name in the Command Line as the first ARG to pass to PxPlus as follows (current directory is assumed to be the install directory):  <br>  <br> "\<install dir>\\pxplus.exe" windx/launcher -arg "Connection" |

## Connection Settings

Each connection can have the following information:

|  |  |
| --- | --- |
| *Connection Name* | Name that is entered to identify the connection. |
| *Connection type* | Type of host, which can be one of the following: *PxPlus Simple Client Server, SSH, Application Server, NThost/NTslave* or *Telnet*. |
| *Server* | This is generally the IP address and/or host name. |
| *Port* | Connection port, which can vary based on the *Connection type*. By default, Port 4093 is used by the Simple Client Server, Port 10000 for NThost or the Application Server, or Port 23 for Telnet. |
| *Secure* | The Simple Client Server, Application Server and NThost/NTslave support SSL and allow this option to be selected, if needed. |
| *Reset WindX/CS Security* | This button (located in the upper right corner of the WindX launcher) is used to reset the WindX/CS security settings. If selected, a prompt asking to confirm the security reset will display.<br>*(The Reset WindX/CS Security button was added in PxPlus 2019.)* |
| *Parameter(s)* | For additional connection parameters that can be specified, see **[Parameters](https://manual.pvxplus.com/windx/connectionmrg#Mark3)**. |
| *Default Host* | Check box that is used to define the connection as the default. |

The

buttons are described below.

|  |  |
| --- | --- |
| *New* | Clears the fields (except *Connection type* and *Port*) for the currently selected connection (settings are not deleted) to make it easier to enter the settings for a new connection.<br>The *Port* resets to the default for the selected *Connection type*; all other fields are cleared.<br>*(The New button was added in PxPlus 2026 Update 1.)* |
| *Save* | Saves the connection settings and adds the saved connection to the list on the left. |
| *Connect* | Connects to the server. |
| *Exit* | Closes the WindX Connection Manager with no further action taken. |
| *Remove Connection* | Deletes the selected connection. Prior to deleting, a confirmation message is displayed.<br>*(The Remove Connection button was added in PxPlus 2026 Update 1.)* |
| *Make Link File* | Creates a link file with the extension **.windx**, which is used as a shortcut for starting the connection in the directory in which this file is located.<br>See **[PxPlus Link File Extensions](https://manual.pvxplus.com/pxplus-installation-and-configuration/customizing-pxplus/pxplus-link-file-extensions)**.<br>*(The Make Link File button was added in PxPlus 2017.)* |

For information on managing connections, see **[Saving, Recalling and Removing a Connection](https://manual.pvxplus.com/windx/connectionmrg#Mark1)**.

For information on COM port and Telnet configurations, see **[WindX Configuration](https://manual.pvxplus.com/windx/legacy-configuration/config)**.

Note:  
WindX debug mode can be enabled by setting %wdx_dbg to 1.

## Saving, Recalling and Removing a Connection

Connections can be named and saved to the **\<*install dir*>/windx/connections.dat** data file. If desired, a "default" connection can be defined. If a default is present when the **Connection Manager** is run, the settings for the connection marked as *Default* will be automatically loaded.

***Creating and Saving a New Connection***

To create a new connection when settings for an existing connection are currently displayed, click the *New* button to clear the fields. Enter the desired *Connection Name*, *Connection type*, and *Server* name, and adjust the *Port* if needed. When done, click the *Save* button.

The new connection is added to the list of saved connections on the left.

***Recalling and Starting a Saved Connection***

Select a connection from the list of saved connections on the left. The settings for the selected connection are displayed on the right. Click the ***Connect*** button to connect to the server.

You can also double click a saved connection to immediately load its settings and connect to the server.

To simplify connections, the **[Make Link File](https://manual.pvxplus.com/windx/connectionmrg#Mark9)** button can be used to create **.windx** link files as shortcuts.

***Removing a Saved Connection***

Select the connection you want to remove from the list of saved connections on the left. Click the *Remove Connection* button, or right click the connection and choose *Remove connection* from the popup menu. A message is displayed, prompting you to confirm the removal of the connection.

## Parameters

The PxPlus Simple Client Server, NThost and the Application Server allow additional connection parameters to be specified:

|  |  |  |
| --- | --- | --- |
|  | ***Simple Client Server*** | Name of program to run |
|  | ***NThost*** | Name of program to run |
|  | ***Application Server*** | Name of 'process' to run |

Note:  
The Parameter(s) field is *not* used for Telnet connections.

To run an

SSH connection, five additional parameters can be specified, as shown in the example below:

![](https://manual.pvxplus.com/migration-assets/4c2631ae8e847b027cc862ef752d20052b621c1141790a7660ca4373c9e3a9ab.png)

The parameters for an SSH connection are:

|  |  |
| --- | --- |
| *User  <br>Password* | Username and/or Password to connect with. |
| *Term* | Enter a terminal type or click the drop-down arrow to select one from the list: *winterm*, *xterm* or *ansi*.<br>*(The Term field was added in PxPlus 2025.)* |
| *PxPlus Path* | Enter the path to the directory where the PxPlus executable is located.<br>*(The PxPlus Path field was added in PxPlus 2025.)* |
| *Private Key Path* | Enter the path to a PuTTY private key (*.ppk*) file to use for SSH authentication or click the Query button (yellow folder) to specify the path.<br>The PuTTY private key file contains the private half of an SSH key pair that PuTTY uses to authenticate you when connecting to an SSH server. It can be generated or converted using PuTTYgen (the PuTTY Key Generator utility).<br>*(The Private Key Path field was added in PxPlus 2026 Update 1.)* |

## Browser Launching

A Web shortcut can be provided for users who are connecting via Simple Client Server or SSH:

***Example:***

|  |  |  |
| --- | --- | --- |
|  | ***For Simple Client Server*** | windx://server:scs/4093/program |
|  | ***For SSH*** | windx://192.168.1.117:ssh/ |

Windows shortcuts *(***.url** files) can be created, which users can put on the desktop.

See **[Launching WindX from a Browser](https://manual.pvxplus.com/windx/browser)**.

Note:  
The registry entries are created automatically when a user installs WindX; therefore, once WindX has been installed, all that is needed is the URL.

## See Also

**[Link File Extensions](https://manual.pvxplus.com/pxplus-installation-and-configuration/customizing-pxplus/pxplus-link-file-extensions)  
[\*SSH System Library Utility](https://manual.pvxplus.com/utilities/ssh-systemlibrary)**