# Conditional Detail Groups

> Source: https://manual.pvxplus.com/report-writer/designing-a-report/creating-the-report-layout/conditional-detail-groups

Multiple detail line groups can be defined. The additional detail groups will have conditions associated with them to determine which group will be used to display the contents of a record. For example, if a record has a TYPE$ field, then the user could define a detail line group for each possible TYPE$ value. The first detail line group is the default group. It has no conditions associated with it and is used if the conditions for the other detail groups are not met. A maximum of 98 additional detail groups can be defined.

To add, update or remove detail line groups, select the **Detail Line Groups** tab on the **Groups** window. To invoke the **Groups** window, select *Groups* from the Report Designer *Edit* menu or right click on the data source in the left data pane and select *Define Groups and Group Functions* from the popup menu. Alternatively, click on the cell displaying a small arrow next to a section line in the leftmost column of the layout.

![](https://manual.pvxplus.com/migration-assets/f78b9f85678ce9cd030afc625eeb3435dddfd22e4e00dbf84b5db404f2226b47.jpg)

The

**Detail Line Groups** tab consists of the following:

|  |  |
| --- | --- |
| *Add* | Launches the **[Define Filters](https://manual.pvxplus.com/report-writer/designing-a-report/defining-the-data/data-filters)** window for adding a detail line group. |
| *Remove* | Deletes a selected group. Prior to deleting the group, a message will display. |
| *Properties* | Updates the settings for a selected group. |
| *Move Up  <br>Move Down* | The sequence in which the conditions for each group are tested can be controlled by adjusting their order with the *Move Up/Move Down* buttons.<br>Note:  <br>Detail Group 01 is the default group and cannot be updated, removed or moved. |
| *Use Filler line to fill gap between   <br>last line and page bottom* | ***(Available when "Include Filler line section" check box on the Main panel is selected)***<br>Causes a **[Filler Line](https://manual.pvxplus.com/report-writer/designing-a-report/creating-the-report-layout/filler-line)** to be output between the last detail line on a page and the bottom of the page. |

When a group is added or updated, the conditions associated with the group are set. Any conditions that are assigned use the same filtering mechanism as described in **[Data Filters](https://manual.pvxplus.com/report-writer/designing-a-report/defining-the-data/data-filters)** with the exception that a detail group is being accepted/rejected rather than data.

Multiple detail line groups will display in the Report Designer as separate sections with yellow section headers.

## See Also

**[Grouping the Data](https://manual.pvxplus.com/report-writer/designing-a-report/creating-the-report-layout/grouping-the-data)**