# Report Designer Options

> Source: https://manual.pvxplus.com/report-writer/designer-options/introduction

The **Designer Options** window is used for setting options and preferences that govern the **[Report Designer](https://manual.pvxplus.com/report-writer/designing-a-report/report-designer/overview)** environment.

A **[Suppress Post Report Logic](https://manual.pvxplus.com/report-writer/designer-options/introduction#testing)** option has been added, which is used to suppress the execution of **[Post Report Logic](https://manual.pvxplus.com/report-writer/designing-a-report/report-options/overview#post_rpt)** (if defined in **Report Options** on the **Custom Interfaces** tab) while testing via the *Preview* or *Print* buttons.

*(The Suppress Post Report Logic option was added in PxPlus 2022.)  
(The Post Report Logic option was added in PxPlus 2022.)*

To invoke this window, select *Designer Options* from the Report Designer *Options* menu.

![](https://manual.pvxplus.com/migration-assets/ba240801fd67af87fba48994f4e08fb41ef82a3a0c46f63bd246ee567d342eec.jpg)

This window consists of the following:

|  |  |
| --- | --- |
| **General** |  |
| **Auto Display** | \|  \|  \|<br>\| --- \| --- \|<br>\| *Auto-display HTML output* \| Automatically display HTML reports using the default browser when reports are generated in this format from the Report Designer. \|<br>\| *Auto-display PDF output* \| Automatically display PDF reports using the PDF reader when reports are generated in this format from the Report Designer. \| |
| **Units of Measure** | \|  \|  \|<br>\| --- \| --- \|<br>\| *Metric Ruler* \| Display the Designer layout using metric (centimeter) units. There will be a difference in the size of the display when switching to and from metric display. \| |
| **Testing Parameters** | \|  \|  \|<br>\| --- \| --- \|<br>\| *Use Test Mode* \| Restricts the number of records processed when a report is generated. A processed record is one that is included in the report; i.e. it has not been rejected by the filtering process. \|<br>\| *Number of records to process* \| Specify the number records to be processed when in Test Mode. \|<br>\| *Suppress Post Report Logic* \| Suppresses the execution of **[Post Report Logic](https://manual.pvxplus.com/report-writer/designing-a-report/report-options/overview#post_rpt)** that has been defined for the report while testing via the *Preview* or *Print* buttons on the Report Designer tool bar. \|<br>\| *Auto Save before preview/print* \| Allows you to automatically save the current report definition prior to testing the report by choosing *Preview* or *Print*. \|<br>The options *Use Test Mode*, *Suppress Post Report Logic* and *Auto Save before preview/print* are also available at the bottom of the main **[Report Designer](https://manual.pvxplus.com/report-writer/designing-a-report/report-designer/overview)** panel.<br>*(The Auto Save option was added in PxPlus 2016.)  <br>(The Suppress Post Report Logic option was added in PxPlus 2022.)* |
| **Default Row Height** | Set the default line height (in inches or cm, depending on the **Units of Measure** setting) for new reports and new lines.<br>An *Auto* setting will determine the default line height based on the size of the default font. (By default, the *Auto* check box is selected.) |
| **Default Column Width** | Set the column width (in inches or cm, depending on the **Units of Measure** setting) for new reports and new columns. The default is a half-inch or 1 cm (depending on the **Units of Measure** setting). |
| **Numeric Format** | \|  \|  \|<br>\| --- \| --- \|<br>\| *Default numeric format mask* \| Specify the default numeric format mask to use for group functions. (This can also be set in **[Group Functions](https://manual.pvxplus.com/report-writer/designing-a-report/creating-the-report-layout/group-functions)**.) \| |
| **Other Options** | \|  \|  \|<br>\| --- \| --- \|<br>\| *Inherit attributes from column on left when inserting a column* \| If this option is selected, when a column is inserted, the cell attributes (font, colors, alignment, word-wrap and borders) from the previous column (on the left) are inherited on a cell-by-cell basis. If column 1 is inserted or the option is not selected, then the column cells will be assigned default attributes.<br>Note:  <br>If the cell to the left is a joined cell (see [Join](https://manual.pvxplus.com/report-writer/designing-a-report/creating-the-report-layout/formatting#join)), the inherited attributes would be those of the cell if it were not joined and therefore may not match the attributes displayed when joined.<br>This option is also available at the bottom of the main Report Designer panel. \|<br>*(The Inherit attributes from column on left when inserting a column option was added in PxPlus 2023.)* |
| **Font** |  |
| **Font** | Specify the default font, font size (point size) and font style to use for new reports.<br>The font name may be selected from the list provided or entered in the input box above this list. This allows you to select a font that is not resident on the system. |
| **Library** |  |
| **Associate Libraries** | Add or remove default libraries. Default libraries are automatically associated with new report definitions. |
|  |  |
| *Save Settings* | Saves the current settings for future sessions when the Report Designer is closed. |