# MSGBOX Popup Message Box

> Source: https://manual.pvxplus.com/pxplus-user-guide/graphical-user-interfaces/interface-windows/msgbox

The **[MSGBOX](https://manual.pvxplus.com/directives/msgbox)** directive is used to display a window with a message in the middle of the screen. Various options are available as to which buttons, icons and behaviour combinations may be applied to the window:

|  |  |  |
| --- | --- | --- |
| ***Buttons:*** |  |  |
|  | **OK** | OK only |
|  | **CANCEL** | OK, Cancel |
|  | **RETRYCANCEL** | Retry, Cancel |
|  | **ABORT** | Abort, Retry and Ignore |
|  | **YESNO** | Yes, No |
|  | **YESNOCANCEL** | Yes, No, Cancel |
|  | **1** (or **2** or **3**) | Default button number |
|  | **TOP** or **^** | Always on top (forces foreground window) |
|  | **TIM**=*num* | Maximum time-out value in integer seconds for closing automatically. The returned value is "TIMEOUT". |
| ***Valid Icons (in graphics mode only):*** |  |  |
|  | **STOP** | Stop sign |
|  | **INFO** | Lowercase 'i' in a circle |
|  | **QUESTION** or **?** | Question mark |
|  | **EXCLAMATION** or **!** | Exclamation mark |
| ***Miscellaneous:*** |  |  |
|  | **BEEP** | Send associated sound |

The user's message box button selection is returned in a string variable. Possible associated return values are "**ABORT**", "**CANCEL**", "**IGNORE**", "**NO**", "**OK**", "**RETRY**" or "**YES**", depending on the button selection required. See **[MSGBOX](https://manual.pvxplus.com/directives/msgbox)** directive for syntax details.

***Example:***

```
X$="John Smith"
MSGBOX "Your entry ["+X$+"] cannot be found."+SEP+"Do you wish to continue?", "Warning","YESNO,2,!",yesno$
PRINT X$
NO
```

![](https://manual.pvxplus.com/migration-assets/d9922009610bf52648e534b5fb297e63493d319e0ec3c670654f381d58c3de67.jpg)

In the above example, a **[SEP](https://manual.pvxplus.com/functions/sep)** has been inserted in the message to break it to a second line. The *Yes* and *No* buttons have been specified (**YESNO**). The default is set to 2. An **!** *exclamation* icon is displayed.

***Example:***

```
MSGBOX "The report is completed","F.Y.I.","TIM=3"
```

In this example, the message box will self-destruct in 3 seconds.

## Customizing the Message Box

It is possible to override the Windows standard message box and instead use a message box that you develop yourself. The **['MX'](https://manual.pvxplus.com/parameters/mx)** system parameter, if set, will redirect to sub-programs **\*ext/msgbox.gui** (user-defined) or \***ext/system/msgbox.gui** (PxPlus-supplied) to process the request instead of the standard Windows message box. By default, PxPlus sets the **'MX'** parameter to ***On*** when **\*ext/msgbox.gui** is found to exist.

The **msgbox.gui** sub-program creates and displays a message box that is similar to the standard Windows system message box but will use Windows 7-style buttons if the **['4D'](https://manual.pvxplus.com/mnemonics/4d)** mnemonic is enabled or use buttons with squared corners if using Windows 10. In addition, it will use the currently selected Windows graphic font. Unlike the standard Windows message box, the message will be displayed centered on the current window, and up to three custom buttons can be defined.

Note:  
When ['MX'](https://manual.pvxplus.com/parameters/mx) is set, MSGBOX commands entered in console mode or executed within an EXECUTE command *cannot* be followed by any other command (as MSGBOX will be executing a CALL without a return address).

Several internal bitmap names for standard Windows bitmaps are available for displaying the embedded OS icons used by the normal message box API call: **!Sys_Stop**, **!Sys_Question**, **!Sys_Info** and **!Sys_Exclamation**.

The button text **ABORT**, **CANCEL**, **IGNORE**, **NO**, **OK**, **RETRY**, **CONTINUE** and **YES** are included in the system message library file (i.e. *\*mlfile.en*) to provide support for multilingual systems. The message numbers are defined as follows:

| **MSG( ) Number** | **String** |
| --- | --- |
| 160 | "OK" |
| 161 | "OK,Cancel" |
| 162 | "&Retry,Cancel" |
| 163 | "&Abort,&Retry,&Ignore" |
| 164 | "&Yes,&No" |
| 165 | "&Yes,&No,&Cancel" |

Use the **[DEF MSG](https://manual.pvxplus.com/directives/def-msg)** directive to temporarily override the message text associated with the **MSG( )** number. This directive allows messages to be changed on the fly.

***Example:***

**MSG(164)** "&Yes,&No" can be changed to another language:

```
DEF MSG(164) = "&Oui,&Non"
```

Note:  
To permanently define different system messages for a different language, create a *\*mlfile.xx* for a different language and use the \*msgupd program to define all the messages.  
  
See [Customizing System Messages for Different Languages](https://manual.pvxplus.com/pxplus-system-programs-and-files/message-library/overview#customizing).

## Using Custom Buttons

When using the **\*ext/system/msgbox.gui** program, you can define up to three custom buttons to display on a custom message box.

```
BTN1=text$
BTN2=text$
BTN3=text$
```

***Where:***

|  |  |
| --- | --- |
| *text* | Indicates the text to display on the custom button. When the button is selected, the *selection$* value will be set to **BTN1**, **BTN2** or **BTN3**. |

***Example:***

```
MSGBOX "What is the correct response?","Answer", "?,BEEP, BTN1=One, BTN2=Two, BTN3=Three,3",X$
```

This example produces the following message box when the **['MX'](https://manual.pvxplus.com/parameters/mx)** system parameter is set and the PxPlus-supplied program **\*ext/system/msgbox.gui** is in use:

![cid:image001.png@01D09881.E5BA7670](https://manual.pvxplus.com/migration-assets/aee528570bc63e1c7b9ff1c3b1b8a43f337dec7225a1afb3e6c03c675d619d4d.jpg)

If the default "Three" button is selected, *X$* will be set to **BTN3**.

## Using Customized Messages with WindX

Use of this facility under WindX requires some additional effort by the developer; i.e. will the subprogram be running on the host or on the workstation. If the program runs on the host, it will transmit the screen drawing information to the workstation just like any other PxPlus program. If the program is to run on the workstation, the host will simply send the **MSGBOX** parameters to WindX, which in turn runs the program locally (assuming it is present).

The setup for WindX is described as follows:

- To run the *host's* msgbox.gui, set the **['MX'](https://manual.pvxplus.com/parameters/mx)** system parameter. No change is required for workstation software.
- To run the *workstation's* msgbox.gui, ensure that the program exists on the workstation, then execute \[wdx\]Set_param 'MX' to set the parameter locally.

This takes advantage of the fact that PxPlus automatically sets **'MX'** based on the existence of a (user-defined) **\*ext/msgbox.gui**. Simply copy the **msgbox.gui** from \*ext/system to the \*ext directory on the host. The system will use it and send screen-drawing directives to the workstation. If it is copied (or installed) to \*ext on the WindX workstation, the system will automatically use it, assuming it is not overridden by the host.

This customizable **MSGBOX** also takes advantage of the **['BEEP'](https://manual.pvxplus.com/mnemonics/beep)** mnemonic.