# PxPlus OLE Server

> Source: https://manual.pvxplus.com/pxplus-user-guide/external-components/pxplus-ole-server/overview

The PxPlus OLE Server (PxPlus.Script) delivers the *reverse functionality* to that of **[PxPlus COM Support](https://manual.pvxplus.com/pxplus-user-guide/external-components/pxplus-com-support/overview)** - it allows external applications to directly invoke and interact with PxPlus and PxPlus objects.

The purpose of this interface is to expose the PxPlus environment to virtually any *outside* COM-compliant application. With the OLE Server running, it is possible to create a PxPlus object and then invoke it from other languages, such as VB, VBScript, Delphi, and C++. You can also use DCOM to invoke the PxPlus object remotely.

For general descriptions of Microsoft OLE and COM, see **[Concepts and Terminology](https://manual.pvxplus.com/pxplus-user-guide/external-components/introduction#terminology)**.

Important Note:

*Prior to PxPlus 2021:* 32-bit PxPlus supported only the Providex.Script name.  
  
*As of PxPlus 2021:* For compatibility purposes, 32-bit PxPlus still ships with pvxcom.exe and pvxscript.dll and supports the Providex.Script name. This is in addition to having pxpcom.exe and pxpscript.dll and supporting the PxPlus.Script name.  
  
It is not possible to register and use both the 32-bit and 64-bit pxpcom.exe and pxpscript.dll at the same time. Only one can be registered at a time.

## Registration of the OLE Server

Access to PxPlus.Script requires running *pxpcom.exe*, which is included with the installation of PxPlus for Windows. Use of the interface may require a separately purchased activation key apart from your initial PxPlus for Windows activation. Further to this, *pxpcom.exe* may need to be registered manually on your Windows OS (if registration did not occur with your installation of PxPlus).

Note:  
You will be required to run a Command prompt or Windows PowerShell as an administrator to allow the registry updates to take effect.

To add *pxpcom.exe* to the Windows registry, enter the following from the Command line:

*path*\\pxpcom.exe /regserver

***Where:***

*path* is the directory of the PxPlus version you are running.

This can be ***unregistered*** by entering the following from the Command line:

*path*\\pxpcom.exe /unregserver

One way to verify that the executable *pxpcom.exe* is registered correctly is by running the following VB script:

```
Set pxp = CreateObject("PxPlus.Script")
pxp.Init ""
pxp.execute("v=tcb(29)")
nm=pxp.Evaluate("v")
MsgBox "Version =" & nm
set pxp=nothing
```

## Using PxPlus.Script

The interface is invoked in an external language via PxPlus.Script:

|  |  |  |
| --- | --- | --- |
|  | **VB** | Set pxp = CreateObject("PxPlus.Script") |
|  | **Delphi** | pxp:=CreateOleObject("PxPlus.Script") |
|  | **Java** | var oPxp = new ActiveXObject("PxPlus.Script"); // Java |

Six ***methods*** are available for use with PxPlus.Script:

|  |  |
| --- | --- |
| **Init**(*path*) | Called before accessing any other method in the script engine in order to set the working directory for the server and perform binding to the PxPlus ***dll*** layer.<br>The *path* should be set to the desired working directory or blank to indicate the current directory. (In most cases, the current directory will be the system directory.) |
| **Execute**(*stmt*) | Invoked to execute any PxPlus Command statement. |
| **Evaluate**(*expr*) | Evaluates and returns the expression provided and returns its value as a variant. (It can be used as either a numeric or a string.) |
| **Run**(*prog*) | Runs the specified program. This method does not return until the program ends. |
| **Reset( )** | Closes all local files and clears variables (executes a **BEGIN**). |
| NewObject(*name, params ...***)** | Creates a new object of the specified name and returns an object reference. See **[Additional Properties](https://manual.pvxplus.com/pxplus-user-guide/external-components/pxplus-ole-server/overview#Mark1)**. |

Three ***properties*** are also associated with the interface:

|  |  |  |
| --- | --- | --- |
|  | **Instance** | Returns a unique string to identify the server during its lifetime. |
|  | **State** | Returns the state of the server: 0 *(zero)* = Uninitialized; 1 = Initialized. |
|  | **Parameter** | Read/write property used to access the specified PxPlus parameter. |

***Additional Properties***

To create an object within the OLE Server, the method **NewObject** is used. It returns an object identifier to the PxPlus object that was created. Along with the PxPlus defined properties and methods, the OLE server adds the following properties:

|  |  |  |
| --- | --- | --- |
|  | **Instance** | Returns a unique identifier of the PxPlus.Script object that was used to create the automation object. This is important because the automation object cannot be passed to another PxPlus.Script server. |
|  | **ScriptObject** | Returns the parent PxPlus.Script object. |
|  | **CmdHandle** | Returns the PxPlus handle to which the automation object is tied. |

***Naming Conventions***

Be aware that COM is generally data-type insensitive; i.e. it does not support the **$** or **%** suffix. This can cause a problem when dealing with PxPlus via the OLE Server since, in PxPlus, you can have **Cust_no$** and **Cust_no** (as two unique data variables).

To avoid this issue, the OLE Server mandates that all property references indicate the property type in the first character of the property name:

|  |  |
| --- | --- |
| **s** | For string variables |
| **n** | For numeric variables |
| **i** | For integer variables |
| **o** | For object variables ***(Required)*** |

***Example:***

```
Cat$ becomes sCat
Dog becomes nDog
Pig% becomes iPig
```

These prefixes are ***only*** for use by programs using the OLE Server, ***not*** by the PxPlus application itself. This means that the property **Cust_no$** in PxPlus would be **sCust_no** when referenced by the OLE Server, and the property **Cust_no** in PxPlus would be **nCust_no**, etc.

Important Note:

*Do not* use these prefixes in the property definition. Use of the o prefix allows the specification of properties and/or methods within PxPlus objects to be declared themselves as objects.

## PxPlus as Windows Script

Through the use of the OLE server, PxPlus itself can become a script language for any Windows system. PxPlus files saved with a ***.pvs*** suffix may be passed to the PxPlus script engine to be executed as a script in Windows applications.

***Using PxpScript***

The PxPlus-based script files are exposed through *pxpscript.dll*, a specially built interface that utilizes IActiveScript and IActiveScriptParse for access to MS scripting (hosts such as IIS, WScript, MS Script Control, etc.). Code execution is passed to *pxpcom.exe*, which sends commands to *pvxwin32.dll*. The whole process looks like the following:

Windows Application --> PxpScript --> OLE Server --> PxPlus

The *pxpscript.dll* must be installed in the same directory as *pxpcom.exe* and *pvxwin32.dll*. As with *pxpcom.exe*, the *pxpscript.dll* may need to be registered manually on your Windows OS (if registration did not occur with your installation of PxPlus). Adding PxpScript to the registry ensures the creation of:

- Default COM registry entries for the ActiveX library.
- WScript.exe and CScript.exe associations in the registry. This allows you to create text-based scripts that can be saved with a ***.pvs*** extension and then be invoked automatically in WScript/CScript (the scripting engine uses the associations to determine which ActiveScript engine will be invoked).

***Usage Notes***

Script definitions vary slightly from regular PxPlus language syntax in that the text is basically passed to PxPlus as a series of execute commands. However, there is an exception: any code that starts with a statement label and ends with **END** will be considered a program and built as if it were typed in. After the **END** directive, you can then issue a **GOTO** *label;**RUN*** to begin execution of the code. (The short cut is **#** *xxxxx* where *xxxxx* is the *label.)*

Script-based programs do not recognize line numbers in the same manner as PxPlus. When an error occurs in a script, the line number reported will reflect the (sequential) line number from the original script input file/document.

Host applications can usually expose what are referred to as "*global named items*". These items are COM objects that the host exposes to the script interface to allow the script to interact with the hosting application.

***Example:***

WScript exposes wscript, wsh; IE exposes window; IIS exposes response, request, etc.

Note:  
It is the developer's responsibility to understand the syntax related to the environment for which he/she will be developing scripts. Named items are based on the context of the host; therefore, the same code may not be valid in all environments.

***Sample Script***

The following is a ***.pvs*** file that may be executed from Internet Explorer:

```
10 !preinput -1300;preinput 0;input *
15 ! Uncomment line 10 to get the trace window
20 objArgs = %WScript'Arguments
30 MSGBOX str(%WScript'*)
40 MSGBOX str(objArgs'Count)
50 i=objArgs'Count-1
60 WHILE (i >= 0)
70 MSGBOX Str(i); MSGBOX objArgs'_$(i)
75 i--
80 WEND
90 MSGBOX %WSH'*
100 END
#10 ! GOTO line 10 and RUN
MSGBOX "Done"
```

This logic executes as follows:

Add lines 10 to 100 to the engine.  
Execute a GOTO 10.  
Execute a RUN. The code will stop running at line 100 (and the script interface gets control back).  
Execute MSGBOX directly.