# System Parameters

> Source: https://manual.pvxplus.com/parameters

System parameters are used at start up to define a system's operation under PxPlus. Each consists of a two-character code enclosed in single quotes. Most parameters are Boolean switches (0 or negative sign indicates ***Off***, 1 or no sign indicates ***On***), but some require specific values in order to be set. See **[Setting/Resetting Parameters](https://manual.pvxplus.com/parameters#Mark1)** below.

Note:  
In this reference, some parameters are *always* described with an = equals sign to indicate that they are set (On) using non-Boolean values; e.g. 'BY'= or 'DW'=.

Most often, system parameters are set only once at the beginning of an application, typically in a start_up program; however, any system parameter can be set or reset in your software at any time, whenever required.

For related information and examples, see [SET_PARAM Directive](https://manual.pvxplus.com/directives/set-param), [PRM System Variable](https://manual.pvxplus.com/variables/prm), and [PRM( ) Function](https://manual.pvxplus.com/functions/prm).

For a complete list of system parameters, see **[System Parameters List](https://manual.pvxplus.com/parameters-list-introduction)**.

## Setting/Resetting Parameters

The **[SET_PARAM](https://manual.pvxplus.com/directives/set-param)** directive and the PxPlus \*UCP utility allow you to alter the current settings of system parameters. The specific method for setting/resetting each parameter is explained with each definition.

***Examples:***

```
SET_PARAM 'AH' Switches Alternative Heading On
SET_PARAM -'AH' Switches Alternative Heading Off
SET_PARAM 'AH'=0 Switches Alternative Heading Off
SET_PARAM 'BY'=0 Sets the Base Year to Julian calendar base
SET_PARAM 'BY'=1970 Sets Base Year to 1970
```

***Off:*** Parameter shows a *negative sign* or is set to equal *0 (zero)*.  
  
***On:*** Parameter is *not negative* or is set to equal a *specific value*.

## Parameter Defaults

The [PRM](https://manual.pvxplus.com/variables/prm) system variable can be used to return a string of the current system parameters and their values. (Some will be hidden from the **PRM** list unless they are actually set.)

**PRINT PRM** lists the following defaults in PxPlus for Windows 32-bit:

```
PRINT PRM !
-'3D',-'AD',-'AH','AI'=10,-'B0','BF'=10,-'BT',-'BX','BY'=1970,-'CD','CS',
'CT'=0,'CU'=36,-'D0',-'DC','DF'=0,'DL'=0,'DP'=46,'DT'=0,'DW'=0,-'EG','EL'=0,
-'EO',-'ES',-'EX',-'F4','FB'=5,-'FC','FF'=0,-'FI','FO'=0,-'FU',-'FL','FP',
'FS'=138,-'FT',-'FX',-'F,',-'I0',-'I2','IC',-'IM','IR','IS'=5,-'IZ',-'KR',
'LB'=4,-'LC',-'LD',-'LE','LS'=1,-'LU',-'LZ','MB'=0,-'MC','MF'=50,-'MP','NE',
-'NI',-'NK',-'NL',-'NN',-'NR',-'OC','OL'=25,'OM',-'OP','OR','OW'=0,'PC'=0,
'PD'=2,-'PO',-'PU','PW'=36,-'PZ','QF'=1,'Q_'=2,'Q^'=2,-'QS',-'QT',-'RI',
'RN'=1,'RP',-'RR',-'RS',-'SC',-'SD',-'SF',-'SK','SL'=32,-'SP',-'SR','SV'=1,
'SZ'=32000,-'TB','TC'=0,'TH'=44,-'TL',-'TN',-'TT',-'TU',-'TX','VP'=48,'VR'=0,
'VW'=0,'WB','WD'=10000,-'WF','WH'=0,'WI'=1000,-'WK','WT'=2,-'XC',-'XF',-'XI',
-'XT',-'ZP',-'DD','!B'=3,'!U'=0,-'1U'
```

## Saving/Restoring System Parameters

To avoid conflicts with other software components, it is ***strongly*** recommended that you save the current settings for parameters you need to change and then reset them when done.

Note:  
The ['BX'](https://manual.pvxplus.com/parameters/bx) parameter is the only exception to this recommendation since it affects a series of system parameters. *Never* attempt to save/change/restore 'BX'. It should be set/reset only at the start of a session.

***Example*:**

```
0010 sv_ex=prm('ex'); SET_PARAM -'EX'
.....
9900 SET_PARAM 'EX'=sv_ex
```
