# V_SCROLLBAR Create/Control Vertical Scrollbar

> Source: https://manual.pvxplus.com/directives/v-scrollbar

## Formats

|  |  |
| --- | --- |
| 1\. [Define/Create](https://manual.pvxplus.com/directives/v-scrollbar#Mark5)*:* | **V_SCROLLBAR** *ctl_id*, @(*col,ln,wth,ht*) **\[**,*ctrlopt*\] |
| 2\. [Define at Edge of Window](https://manual.pvxplus.com/directives/v-scrollbar#Mark8)*:* | **V_SCROLLBAR** *ctl_id* **WINDOW \[***,ctrlopt*\] |
| 3\. [Delete](https://manual.pvxplus.com/directives/v-scrollbar#Mark10)*:* | **V_SCROLLBAR REMOVE** *ctl_id* **\[**,**ERR**=*stmtref*\] |
| 4\. [Disable/Enable](https://manual.pvxplus.com/directives/v-scrollbar#Mark12)*:* | **V_SCROLLBAR {** **ENABLE** \| **DISABLE }** *ctl_id* **\[**,**ERR**=*stmtref*\] |
| 5\. [Set Focus](https://manual.pvxplus.com/directives/v-scrollbar#Mark14)*:* | **V_SCROLLBAR GOTO** *ctl_id* **\[**,**ERR**=*stmtref*\] |
| 6\. [Read Setting](https://manual.pvxplus.com/directives/v-scrollbar#Mark16)*:* | **V_SCROLLBAR READ** *ctl_id, setting, max* **\[***,rgn_chg*\] \[*,arrow_chg*\] \[,**ERR**=*stmtref*\] |
| 7\. [Update](https://manual.pvxplus.com/directives/v-scrollbar#Mark19)*:* | **V_SCROLLBAR WRITE** *ctl_id, marker, max* **\[**,**ERR**=*stmtref*\] |
| 8\. [Hide/Show](https://manual.pvxplus.com/directives/v-scrollbar#Mark21)*:* | **V_SCROLLBAR { HIDE \| SHOW }** *ctl_id* **\[**,**ERR**=*stmtref*\] |

***Where***

|  |  |
| --- | --- |
| @(*col,ln,wth,ht*) | Position and size of the vertical scrollbar region. Numeric expressions. Column and line coordinates for top left corner, width in number of columns and height in number of lines. |
| *arrow_chg* | Amount to increase/decrease the **V_SCROLLBAR** setting when the user selects the arrow at the top/bottom edge of the vertical scrollbar. Numeric expression. (***Default***: 1) |
| *ctl_id* | Unique logical identifier for a vertical scrollbar (any integer -32000 to +32000). Avoid integers that conflict with keyboard definitions (e.g. 4 cancels CTL=4 for the **F4** key) or [Negative CTL Definitions](https://manual.pvxplus.com/appendix/negative-ctl-definitions). |
| *ctrlopt* | Control options. The only supported option for **V_SCROLLBAR** is:<br>\|  \|  \|<br>\| --- \| --- \|<br>\| **OPT**=*char$* \| Single character parameter/option:<br>"D"<br>*Disabled*. User cannot access the scrollbar.<br>"d"<br>Scrollbar is permanently disabled (cannot be enabled).<br>"H"<br>*Hide*. Do not display the scrollbar.<br>"A"<br>*Auto*. Generate CTL signal for each movement.<br>"s"<br>*Scroll*. Allow scroll within resizable/scrollable dialogue box. \| |
| *marker* | Relative position to set as the **V_SCROLLBAR** *marker*. Numeric expression between 1 and the maximum. |
| *max* | Logical maximum value of the **V_SCROLLBAR**. Numeric expression. |
| *rgn_chg* | Amount to increase/decrease the **V_SCROLLBAR** setting when the user selects the region left/right of the marker. Numeric expression. (***Default***: max/width) |
| *setting* | Numeric variable to receive the current scrollbar setting. |
| *stmtref* | Program line number or statement label to which to transfer control. |

## Description

Use the **V_SCROLLBAR** directive to create a vertical scrollbar control object on the screen. Your program logic can read and adjust a value by increments to control logical record position within a file every time the user moves the vertical scrollbar.

Use either **V_SCROLLBAR** Format 1 or Format 2 to define or create a vertical scrollbar. The value in *ctl_id* gives the vertical scrollbar a unique identifier. This is generated as a CTL value whenever the vertical scrollbar is selected and changed.

***Vertical Scrollbar Properties***

The [Apostrophe Operator](https://manual.pvxplus.com/appendix/apostrophe-operator) can be used with the unique logical identifier (*ctl_id*) to dynamically read and alter a wide variety of control attributes (properties) directly from the programming language.

See **[V_SCROLLBAR Properties](https://manual.pvxplus.com/control-object-properties/vscrollbar-properties)** for the list of properties available for manipulating a vertical scrollbar.

## Format 1

***Create***

**V_SCROLLBAR** *ctl_id*,@(*col,ln,wth,ht*)\[,*ctrlopt*\]

Use this format to create a vertical scrollbar inside the current window.

***Example:***

```
v_scrollbar 100,@(70,2,2,20)
```

This example defines a vertical scrollbar that is 2 columns wide, 20 lines high, starting at column 70 on line 2. Whenever the scrollbar is selected, a CTL=100 is generated.

## Format 2

***Define at Edge of Window***

**V_SCROLLBAR** *ctl_id* **WINDOW**\[,*ctrlopt*\]

Use the **V_SCROLLBAR** format with **WINDOW** to create a vertical scrollbar at the edge of the window.

## Format 3

***Delete***

**V_SCROLLBAR REMOVE** *ctl_id*\[,**ERR**=*stmtref*\]

Use the **V_SCROLLBAR REMOVE** format to delete the vertical scrollbar.

## Format 4

***Disable/Enable***

**V_SCROLLBAR** {**DISABLE** | **ENABLE**} *ctl_id* \[,**ERR**=*stmtref*\]

Use the **V_SCROLLBAR DISABLE** format to gray out a vertical scrollbar so that it will be visible but inaccessible to users. To reactivate it, use **V_SCROLLBAR ENABLE**.

## Format 5

***Set Focus***

**V_SCROLLBAR GOTO** *ctl_id*\[,**ERR**=*stmtref*\]

Use the **V_SCROLLBAR GOTO** format to set the focus on the vertical scrollbar, ready for the user's next action.

## Format 6

***Read Setting***

**V_SCROLLBAR READ** *ctl_id*, *setting*, *max*,\[*rgn_chg*\]\[,*arrow_chg*\]\[,**ERR**=*stmtref*\]

Use this format to read the current setting of the vertical scrollbar. Once a new position is selected, you must read it before your application can use the value to update the actual **V_SCROLLBAR** position.

***Example:***

```
0120 v_scrollbar read 100,X,1000
0130 v_scrollbar write 100,X,1000
```

Line 0120 reads the scrollbar position relative to 1000 and line 0130 updates the settings.

## Format 7

***Update***

**V_SCROLLBAR WRITE** *ctl_id*,*marker*,*max*\[,**ERR**=*stmtref*\]

Use the **V_SCROLLBAR WRITE** format to update or write the **V_SCROLLBAR** settings.

## Format 8

***Hide/Show***

**V_SCROLLBAR** {**HIDE** | **SHOW**} *ctl_id*\[,**ERR**=*stmtref*\]

With the **V_SCROLLBAR HIDE** format, the scrollbar remains active but is not displayed. It is still accessible programmatically. Use the **SHOW** format to restore the display and user access.

## See Also

**[V_SCROLLBAR Properties](https://manual.pvxplus.com/control-object-properties/vscrollbar-properties)**  
[H_SCROLLBAR Create/Control Horizontal Scroll Bar](https://manual.pvxplus.com/directives/h-scrollbar)  
[H_SCROLLBAR Properties](https://manual.pvxplus.com/control-object-properties/hscrollbar-properties)

## Example

```
0100 ! 100 - Vertical Scrollbar Example
0110 let VAL=1,MX=400,BJMP=25,SJMP=1
0120 v_scrollbar 101,@(6,14,1,10)
0130 v_scrollbar 102,@(15,14,2,10)
0140 v_scrollbar 103,@(25,14,3,10)
0150 v_scrollbar 104 window
0160 input (0,hlp="V_SCROLLBAR")@(40,18),"Select...: ",'CL',X$
0170 if ctl<101 or ctl>104 then goto 0210
0180 v_scrollbar read ctl,VAL,MX,BJMP,SJMP
0190 v_scrollbar write ctl,VAL,MX
0200 print @(40,19),"Selection:",ctl,":",str(VAL),'CL',; goto 0160
0210 if ctl=0 or ctl>=3 then stop else goto 0160
```