# FIND RECORD Locate & Read Data Record

> Source: https://manual.pvxplus.com/directives/find-record

## Format

**FIND RECORD** (*filespec*\[,*fileopt*\])*var$*

***Where:***

|  |  |
| --- | --- |
| *filespec* | Can be a numeric expression indicating the open channel number to use or a string expression containing the pathname or table name (if string is prefixed by the keyword **TABLE**) of the file to use. |
| *fileopt* | Supported file options (see **[File Options](https://manual.pvxplus.com/appendix/input-output-and-control-options#Mark1)**):<br>\|  \|  \|<br>\| --- \| --- \|<br>\| **BSY**=*stmtref* \| Traps Error #0: Record/file busy \|<br>\| **DIR**=*num* \| Direction indicator (Not supported with **\[WDX\]** tag) \|<br>\| **DOM**=*stmtref* \| Missing record transfer \|<br>\| **END**=*stmtref* \| End-of-File transfer \|<br>\| **ERR**=*stmtref* \| Error transfer \|<br>\| **IND**=*num* \| Record index \|<br>\| **KEY**=*string$/num* \| Record key \|<br>\| **KNO**=*num* \\| *name$* \| File access key number (*num*) or name (*name$*) \|<br>\| **REC**=*name$* \| Record prefix (REC=VIS(*string$***)** can also be used) \|<br>\| **RNO**=*num* \| Record number \|<br>\| **RTY**=*num* \| Number of retries (one-second intervals). This overrides the value defined by the **['WT'](https://manual.pvxplus.com/parameters/wt)** system parameter. \|<br>\| **SIZ**=*num* \| Number characters to read \|<br>\| **TBL**=*stmtref* \| Data translation table \|<br>\| **TIM**=*num* \| Maximum time-out value in integer seconds \|<br>\| *stmtref* \| Program line number or statement label to which to transfer control \| |
| *var$* | String variable. Receives the contents of the record being read. |

*(TABLE support was added in PxPlus 2018.)*

## Description

Use the **FIND RECORD** directive to read a record from the file (channel) you specify. The record's complete data portion will be returned in the string variable you name. Apply the **FIND RECORD** statement when dealing with native-mode operating system files, when exchanging data with applications other than PxPlus, or when you want to read a complete record including data-field separators.

When executing a **FIND RECORD** directive, PxPlus advances the file position to the next record (or the record you specify in a **KEY=** or **IND=** option). Use the **KNO=** option to change the current file access key.

Note:  
If the record is not found when reading using a KEY= or IND= option, the current file position is *not changed* (unlike READ).

## See Also

[EXTRACT Read and Lock Data](https://manual.pvxplus.com/directives/extract)  
[READ Read Data from File](https://manual.pvxplus.com/directives/read)

## Example

```
0020 open lock (2)"NEWFIL"
0030 find record (1,end=1000)R$
0040 write record (2)R$
0050 goto 0030
1000 close (1),(2)
1010 end
```