# END DEF End Definition of Multi-line Function

> Source: https://manual.pvxplus.com/directives/end-def

## Format

**END DEF**

## Description

Use the **END DEF** directive to mark the end of a multi-line function.

In Execution mode, when PxPlus encounters a **DEF FN** directive for a multi-line function, it skips forward until it encounters an **END DEF** directive; that is, control is transferred to the line or statement after the end definition.

If you use an **END DEF** directive without a preceding **DEF FN** directive, PxPlus returns an Error #45: Referenced statement invalid.

## See Also

**[RETURN Return From a Subroutine](https://manual.pvxplus.com/directives/return)**  
**[ESCAPE Interrupt Program Execution](https://manual.pvxplus.com/directives/escape)**  
**[DEF FN Define Function](https://manual.pvxplus.com/directives/def-fn)**

## Example

```
0010 def fnX(A,B)
0020 if A<0 or B<0 escape 40 ! Variables' values must be >=0
0030 return sqr(A^2+B^2) ! Length of hypotenuse
0040 end def
0100 print fnX(7,8)

->run
10.63
```