# Multi-Property Access

> Source: https://manual.pvxplus.com/control-object-properties/multi-prop

The following properties allow an application to set/get values for more than one property for a control in a single command:

|  |  |  |
| --- | --- | --- |
|  | **['\_PropList$](https://manual.pvxplus.com/control-object-properties/properties-list#Mark181)** | Comma separated list of property names to read/write |
|  | **['\_PropValues$](https://manual.pvxplus.com/control-object-properties/properties-list#Mark183)** | String that contains values for each of the properties in **'\_PropList$** |
|  | **['\_PropSep$](https://manual.pvxplus.com/control-object-properties/properties-list#Mark182)** | Character used as a field separator between values |

The ability to handle multiple reads is useful for accessing properties across a WindX connection, particularly when dealing with an object that has a large number of properties such as a grid. This can boost performance and reduce the amount of network traffic.

To retrieve the value of multiple properties, first set **'\_PropList$**, then read **'\_PropValues$**.

***Example:***

```
G1'_PropList$="CurrentColumn,CurrentRow,Value$"
x$=G1'_PropValues$
```

In this example, x$ receives a string containing the values of CurrentColumn, CurrentRow, and Value$, with each field separated by either the standard SEP field separator or with the **'\_PropSep$** character.

Data can then be extracted using **READ DATA**:

```
     read data from G1'_PropValues$ to iol=MYIOL
MYIOL: \
     iolist Col,Row,Value$
```

To set values, first set **'\_PropList$** (if not already set), then set **'\_PropValues$**:

```
G1'_PropValues$="1"+sep+"2"+sep+"Data"

or

G1'_PropValues$=rec(iol=MYIOL)
```

The advantage is that only one packet needs to be sent to WindX to either **SET** or **RETRIEVE** the values of multiple properties. ***Do not*** constantly read fields **'\_PropList$** and **'\_PropSep$** from the control to parse the data returned by **'\_PropValues$**. This would defeat the purpose.

***Example:***

```
read data from G1'_PropValues$,sep=G1'_PropSep$ to iol=cpl("IOLIST "+G1'_PropList$)
```

This example actually results in three exchanges with WindX: one to get **'\_PropSep$**, the second for **'\_PropList$**, and the third for **'\_PropValues$**. The separator character and list should be maintained within the application code and should not be retrieved from the control.