# OCX Controls

> Source: https://manual.pvxplus.com/automation-in-pxplus/advanced-topics/ocx-controls

The DLL container control exposes all the "ambient" properties that are required by OCX controls. These include *foreground/background* color, *message reflection*, *user mode,* etc.

User mode is the only ambient property that is directly available to the PxPlus programmer; the rest are handled by the DLL. User mode is special in that it tells the OCX control if it should act as a design-time control or as a run-time control.

***Example:***  
  
Control ***A*** displays designer toolbars when *UserMode* = *false* but hides these when *UserMode* = *true*. In PxPlus, this property is accessed via the **'PVXMODE** property. Setting **PVXMODE** = 0 sets *UserMode* to *false* (design-time). Any non-zero value will set *UserMode* to *true* (run time).

The DLL also supports OCX control property sheet activation by way of the F2 key. To display an OCX controls property sheet (if it has one), set focus to the control and press F2.