# Labels/Logical Statement References

> Source: https://manual.pvxplus.com/appendix/labels-logical-statement-references

PxPlus supports the use of logical statement references (labels) in lieu of line number references in your applications. PxPlus supplies a set of built-in labels (keywords with the leading asterisk) that can be used wherever you would use a statement reference (line number or line label).

Note:  
Some of the logical statement labels and the directives they emulate will remove an item for your stack and perform a RESET.

The built-in PxPlus labels/logical statement references are:

|  |  |  |
| --- | --- | --- |
|  | **\*BREAK** | Emulates **[BREAK Immediate Exit of Loop](https://manual.pvxplus.com/directives/break)** |
|  | **\*CONTINUE** | Emulates **[CONTINUE Initiates Next Iteration of Loop](https://manual.pvxplus.com/directives/continue)** |
|  | **\*END** | Emulates **[END Halt Execution of Program](https://manual.pvxplus.com/directives/end)** |
|  | **\*ESCAPE** | Emulates **[ESCAPE Interrupt Program Execution](https://manual.pvxplus.com/directives/escape)** |
|  | **\*NEXT** | Goes to the beginning of the next line/statement |
|  | **\*PROCEED** | Continues to the next statement in a compound statement or to the beginning of the next line |
|  | **\*RETRY** | Emulates **[RETRY Re-Execute Failing Instruction](https://manual.pvxplus.com/directives/retry)** |
|  | **\*RETURN** | Emulates **[RETURN Return From a Subroutine](https://manual.pvxplus.com/directives/return)** |
|  | **\*SAME** | Goes to the start of the current line/statement |

Note:  
Prior to PxPlus v4.20, the \*CONTINUE and \*BREAK labels and the corresponding directives are not supported for use with [SELECT](https://manual.pvxplus.com/directives/select) / [NEXT RECORD](https://manual.pvxplus.com/directives/next-record) directives. BREAK and \*BREAK commands can now be used in SELECT structures.

## Example

```
A=0,Y$=""
read (1,ind=A++,err=*next)X$;
Y$+=X$;
goto *same
```

## See Also

**[BREAK Immediate Exit of Loop](https://manual.pvxplus.com/directives/break)**  
**[CONTINUE Initiates Next Iteration of Loop](https://manual.pvxplus.com/directives/continue)**  
**[END Halt Execution of Program](https://manual.pvxplus.com/directives/end)**  
**[ESCAPE Interrupt Program Execution](https://manual.pvxplus.com/directives/escape)**  
**[RETRY Re-Execute Failing Instruction](https://manual.pvxplus.com/directives/retry)**  
**[RETURN Return From a Subroutine](https://manual.pvxplus.com/directives/return)**